Prominent & Leading Manufacturer from Vasai, we offer fm 110 digital fluxmeter and fm 112 digital fluxmeter.

FM 110 Digital Fluxmeter

REQUEST CALLBACK

FM 110 Digital Fluxmeter
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 16,000 / UnitGet Latest Price

Product Brochure
Product Details:
Model Name/NumberFM110
Measuring Range0-200,000 Kilo Maxwell Turns
BrandPolytronic
DisplayThree and Half digit seven segment LED display.
Resolution1-200,000 K.M.T. range
ApplicationIndustrial
Accuracy0.5%
ProtectionOver range protection up to 100%
Input Resistance10 Kilo Ohms
DriftLess than 0.5% of full scale per minute on 2,000 K.M.T. range
Output Resistance1 Kilo Ohms
Voltage230VAC
Frequency50 Hz
PhaseSingle

Fluxmeter Model FM 110 is used to measure magnetic induction in the material and as a general purpose magnet measuring instrument.
 
The application of these Fluxmeter includes :
  • Ferro Magnetic Detectors
  • AC-DC Motors
  • Field Surveyors   
  • Loudspeaker
  • Production Test System
  • Hysteresis Loop Tracer
  • Voltage Integration   
  • Magnetic Shielding Effectiveness Tester

Probe:
  • Transverse Hall probe supplied with the equipment is made out of gallium arsenide crystal is 6mm wide and 1mm thick is supplied with one meter of cable length and is enclosed in pen type metal casing.

Standard Search Coils
  • Standard Search Coils are used with Fluxmeter for measuring magnetic flux / flux density. Search Coils can also be made to a suit specific requirement.

Dimension 150mm(L) X 15mm(W) X 3mm(T).
Model SC-10 10 Area Turns
Model SC-100 100 Area Turns
Model SC-1000 1000 Area Turns


Potential Coils
  • Potential Coils are used to measure the magnetic potential of any magnet/magnetic assembly. This measurement helps in deciding the optimum sizes of different magnetic components of the magnetic assembly / circuit.

Model PC-200LD5 200mm Length X 5mm Diameter.
Model SC-300LD8 300mm Length X 8mm Diameter.


Helmholtz Coils
  • Helmholtz Coils consist of two identical coils, separated by a distance equal to the radius of the coil. Measurement of open circuit magnetization of magnets of high coercive force such as Ferrite, Rare Earth Magnets is possible. Measurements made with potential and Helmholtz coils allows to construct the second quadrant magnetization curve of these magnets.

Model HC-200 200mm Diameter.
Model HC-300 300mm Diameter.


Additional Information:

  • Delivery Time: 4-6 weeks
  • Yes! I am interested

    FM 112 Digital Fluxmeter

    REQUEST CALLBACK

    FM 112 Digital Fluxmeter
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 30,000 / UnitGet Latest Price

    Product Brochure
    Product Details:
    Model Name/NumberFM 112
    Measuring Range500 Maxwell Turns to 1.999 X 10 Maxwell Turns full scale
    BrandPolytronic
    DisplayThree and Half digit seven segment LED display
    Scale FactorFour Digit thumbwheel switch adjustable from 500 to 9999
    MultiplierX1, X10, & X100
    ProtectionOver range protection up to 100%
    Input Resistance10 Kilo Ohms
    DriftLess than 0.5% of full scale per minute on X1 multiplier range
    Output Resistance1 Kilo Ohms
    Voltage230VAC
    Frequency50 Hz
    PhaseSingle

    Fluxmeter used in measurement of magnetic induction in material, also used in various magnetic measurements.

    Probe:
    • Transverse Hall probe supplied with the equipment is made out of gallium arsenide crystal is 6mm wide and 1mm thick is supplied with one meter of cable length and is enclosed in pen type metal casing.

    Fluxmeter Accessories
    Standard Search Coils 
    • Standard Search Coils are used with Fluxmeter for measuring magnetic flux / flux density. Search Coils can also be made to a suit specific requirement.

    Dimension 150mm(L) X 15mm(W) X 3mm(T).
    Model SC-10 10 Area Turns
    Model SC-100 100 Area Turns
    Model SC-1000 1000 Area Turns


    Potential Coils
    • Potential Coils are used to measure the magnetic potential of any magnet/magnetic assembly. This measurement helps in deciding the optimum sizes of different magnetic components of the magnetic assembly / circuit.

    Model PC-200LD5 200mm Length X 5mm Diameter.
    Model SC-300LD8 300mm Length X 8mm Diameter.


    Helmholtz Coils
    • Helmholtz Coils consist of two identical coils, separated by a distance equal to the radius of the coil. Measurement of open circuit magnetization of magnets of high coercive force such as Ferrite, Rare Earth Magnets is possible. Measurements made with potential and Helmholtz coils allows to construct the second quadrant magnetization curve of these magnets.

    Model HC-200 200mm Diameter.
    Model HC-300 300mm Diameter.

    Additional Information:

  • Delivery Time: 4-6 weeks
  • Yes! I am interested

     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Schekhar Lolayekar (Partner)
    Polytronic Corporation
    4, Shailesh Industrial Estate No. 3, Navghar, Vasai Road East, Vasai East
    Vasai - 401210, Thane, Maharashtra, India
    Call Us: 
    Call Response Rate: 77%
    Share Us :



    Home  |   Profile   |  Products  |  Site Map  |   Contact Us

    © Polytronic Corporation. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Polytronic Corporation